{"id":2532,"date":"2026-11-21T12:46:51","date_gmt":"2026-11-21T12:46:51","guid":{"rendered":"https:\/\/www.pharglass.com\/glass-ampoule-defect-inspection\/"},"modified":"2026-11-21T12:46:51","modified_gmt":"2026-11-21T12:46:51","slug":"glass-ampoule-defect-inspection","status":"publish","type":"post","link":"https:\/\/www.pharglass.com\/pt\/glass-ampoule-defect-inspection\/","title":{"rendered":"How to Inspect Glass Ampoules for Defects"},"content":{"rendered":"<p>An ampoule is sealed at both ends, so the glass is the only packaging material in contact with the drug. A defect that would be cosmetic on a bottle can become a particulate or a leak in an ampoule. Inspection therefore focuses on a small number of defect types that matter for sterility and for the opening behaviour.<\/p>\n<h2>Defects to look for<\/h2>\n<div class=\"pg-points\">\n<div><b>Stones<\/b><span>Unmelted batch or refractory particles embedded in the glass. They weaken the wall and can shed particles when the ampoule is opened.<\/span><\/div>\n<div><b>Bubbles and air lines<\/b><span>Elongated air inclusions in the wall. Small round bubbles are usually acceptable within a defined limit; long air lines are not.<\/span><\/div>\n<div><b>Scratches and abrasion<\/b><span>Surface damage from handling or contact between ampoules. Deep scratches become crack starters.<\/span><\/div>\n<div><b>Cracks<\/b><span>Any crack is a reject. Check the neck and the base, where stress concentrates.<\/span><\/div>\n<div><b>Dimensional deviation<\/b><span>Body diameter, height, stem diameter and constriction must match the drawing so that filling and sealing work.<\/span><\/div>\n<div><b>Colour variation<\/b><span>In amber ampoules, batch-to-batch colour shift can indicate a glass composition or firing problem.<\/span><\/div>\n<\/div>\n<h2>Visual inspection method<\/h2>\n<p>Inspect against both a black and a white background under diffuse light. A black background reveals bubbles and stones; a white background reveals scratches, haze and colour variation. Rotate the ampoule so that the whole circumference is seen, and inspect the neck and the base separately because defects there are easy to miss.<\/p>\n<p>For stress, a polarised-light viewer shows annealing quality. Residual stress around the neck is common and can cause cracking during opening, so the neck is worth checking even when the body looks clean.<\/p>\n<h2>Sampling and acceptance<\/h2>\n<p>Inspection is normally carried out on an AQL sample rather than on every ampoule. The defect classification matters more than the sample size: cracks and stones are critical defects with a zero or near-zero acceptance number, while minor scratches may be accepted within a defined limit. The acceptance criteria should be written into the specification and agreed before the first lot, not negotiated after a rejection.<\/p>\n<h2>Defects that affect opening<\/h2>\n<p>For colour-break ampoules, the position and depth of the score determine the breaking force. A score that is too shallow will not break cleanly; one that is too deep can produce glass particles. The score should be inspected together with a breaking-force test, because a visual check alone cannot confirm that the ampoule opens within the specified force range.<\/p>\n<h2>Leitura relacionada<\/h2>\n<ul class=\"pg-links\">\n<li><a href=\"\/pt\/products\/glass-ampoules\/\">Ampolas de vidro para injet\u00e1veis<\/a><\/li>\n<li><a href=\"\/pt\/products\/low-borosilicate-ampoules\/\">Low borosilicate and soda-lime ampoules<\/a><\/li>\n<li><a href=\"\/pt\/mastering-ampoule-breakability-a-technical-guide-to-testing-methods-and-compliance\/\">Ampoule breakability testing guide<\/a><\/li>\n<\/ul>\n<p class=\"pg-cta-line\">Need an inspection specification or a sample lot? Contact <a href=\"\/pt\/contacts\/\">nossa equipe de vendas<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>A practical guide to the common glass ampoule defects \u2014 stones, bubbles, scratches, cracks and dimensional deviation \u2014 and how to inspect for them.<\/p>","protected":false},"author":0,"featured_media":2548,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24,15],"tags":[],"class_list":["post-2532","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-glass-ampoules","category-technical-insights","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"_links":{"self":[{"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/posts\/2532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/comments?post=2532"}],"version-history":[{"count":0,"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/posts\/2532\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/media\/2548"}],"wp:attachment":[{"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/media?parent=2532"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/categories?post=2532"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharglass.com\/pt\/wp-json\/wp\/v2\/tags?post=2532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}